{"id":4041,"date":"2023-11-22T17:11:10","date_gmt":"2023-11-22T17:11:10","guid":{"rendered":"https:\/\/www.nanosoft.sd\/store\/?post_type=product&#038;p=4041"},"modified":"2023-11-22T17:12:18","modified_gmt":"2023-11-22T17:12:18","slug":"antspace-hk3-v6","status":"publish","type":"product","link":"https:\/\/www.nanosoft.sd\/store\/product\/antspace-hk3-v6\/","title":{"rendered":"ANTSPACE HK3 V6"},"content":{"rendered":"<div id=\"block1\" class=\"tuple\" data-v-63a32c95=\"\" data-v-1b41da19=\"\">\n<div class=\"info info-specifications\" data-v-63a32c95=\"\" data-v-1b41da19=\"\">\n<p><strong>Specifications<\/strong><\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<h2>Specification Details For ANTSPACE HK3 V6<\/h2>\n<table>\n<tbody>\n<tr class=\"title\">\n<td>Product Overview<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>ANTSPACE HK3 V6<\/td>\n<\/tr>\n<tr>\n<td>Dimensions (L*W*H) (mm)<\/td>\n<td>6058*2438*2896<\/td>\n<\/tr>\n<tr>\n<td>Miner Capacity<\/td>\n<td>210 units -S19 Hyd. &amp; S21 Hyd. Series miner<\/td>\n<\/tr>\n<tr>\n<td>Container Certification<\/td>\n<td>China Classification Society Certification<\/td>\n<\/tr>\n<tr>\n<td>Safety Certification<\/td>\n<td>NFPA 79:2021<br \/>\nUL 508A:2018 R8.21<br \/>\nCSA C22.2 No. 14-18<br \/>\nANSI\/ISO 12100:2012<br \/>\nIEC 60204 Ed 5.1 2009<\/td>\n<\/tr>\n<tr>\n<td>Operating Power(kW)<\/td>\n<td>1047~1050<\/td>\n<\/tr>\n<tr>\n<td>PUE(Power Usage Effectiveness)<\/td>\n<td>1.022(Excluding cooling tower)\/1.032(Including cooling tower)<\/td>\n<\/tr>\n<tr>\n<td>Input Voltage and Frequency<\/td>\n<td>400V\u00b15% 50\/60Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr class=\"title\">\n<td>Detailed Characteristics<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Shipping Weight(T)<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>Operating Weight (T)<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<td>Main Switch of Power Distribution Cabinets(A)<\/td>\n<td>1200*2<\/td>\n<\/tr>\n<tr>\n<td>Rated Current(A)<\/td>\n<td>A:952; B:866<\/td>\n<\/tr>\n<tr>\n<td>Rated Current per Miner(A)<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>Inlet Cable<\/td>\n<td>The inlet cables can withstand high-voltage of above 600V, with the following requirements:<br \/>\nL1 single core cable 600kcMil(300mm\u00b2)x4<br \/>\nL2 single core cable 600kcMil(300mm\u00b2)x4<br \/>\nL3 single core cable 600kcMil(300mm\u00b2)x4<br \/>\nN Single-core cable 600kcMil(300mm\u00b2)x4<br \/>\nPE single-core cable 500kcMil(240mm\u00b2)x2<\/td>\n<\/tr>\n<tr>\n<td>Connection Interface(Cooling Tower)<\/td>\n<td>DN100\uff08ISO2852 PN16\uff09<\/td>\n<\/tr>\n<tr>\n<td>Connection Interface(Plate Heat Exchage Interface)<\/td>\n<td>DN100(GB\/T 9122-2010 PN16 DN100)<\/td>\n<\/tr>\n<tr>\n<td>Flow Rate(m\u00b3\/h)<\/td>\n<td>\uff1e85<\/td>\n<\/tr>\n<tr>\n<td>Quantity of ANTSPACE powered by one 2500kVA Transformer<\/td>\n<td>2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Specification Details For Dry-Wet Towers<\/h2>\n<table>\n<tbody>\n<tr class=\"title\">\n<td>Product Overview<\/td>\n<td colspan=\"1\"><\/td>\n<\/tr>\n<tr>\n<td>Type<\/td>\n<td>Dry-Wet Tower Container Type \uff08EC1 &#8211; DWT\uff09<\/td>\n<\/tr>\n<tr>\n<td>Dimensions(L*W*H)(mm)<\/td>\n<td>6058*2438*2896<\/td>\n<\/tr>\n<tr>\n<td>Heat Dissipation Capacity(kW)<\/td>\n<td>1000<\/td>\n<\/tr>\n<tr>\n<td>Outlet Temperature @ 28\u2103 Wet Bulb Temperature<\/td>\n<td>35\u2103<\/td>\n<\/tr>\n<tr>\n<td>Container Certification<\/td>\n<td>China Classification Society Certification<\/td>\n<\/tr>\n<tr>\n<td>Safety Certification<\/td>\n<td>NFPA 79:2021<br \/>\nUL 508A:2018 R8.21<br \/>\nCSA C22.2 No. 14-18<br \/>\nANSI\/ISO 12100:2012<br \/>\nIEC 60204 Ed 5.1 2009<\/td>\n<\/tr>\n<tr>\n<td>Operating Power(kW)<\/td>\n<td>14~28<\/td>\n<\/tr>\n<tr>\n<td>Motor Rated Voltage and Frequency<\/td>\n<td>400V\u00b15% 50\/60Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr class=\"title\">\n<td>Detailed Characteristics<\/td>\n<td colspan=\"1\"><\/td>\n<\/tr>\n<tr>\n<td>Shipping Weight(T)<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>Operating Weight\uff08T\uff09<\/td>\n<td>13<\/td>\n<\/tr>\n<tr>\n<td>Connection Interface<\/td>\n<td>DN125(ISO2852 PN16)<\/td>\n<\/tr>\n<tr>\n<td>Water Resupply Pipe Interface<\/td>\n<td>DN40(Internal thread)<\/td>\n<\/tr>\n<tr>\n<td>Drain Pipe Interface<\/td>\n<td>DN65(Internal thread)<\/td>\n<\/tr>\n<tr>\n<td>Noise Level @25\u2103, 15m<\/td>\n<td>70dBA<\/td>\n<\/tr>\n<tr>\n<td>Water Consumption(m\u00b3\/h)<\/td>\n<td>0.7~1.3m\u00b3\/h<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Specification Details For Dry Cooler Towers<\/h2>\n<table>\n<tbody>\n<tr class=\"title\">\n<td>Product Overview<\/td>\n<td colspan=\"1\"><\/td>\n<\/tr>\n<tr>\n<td>Type<\/td>\n<td>Dry Cooler Towers Container Type \uff08EC2 -DT\uff09<\/td>\n<\/tr>\n<tr>\n<td>Number<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Dimensions(L*W*H)(mm)<\/td>\n<td>6058*2438*2896<\/td>\n<\/tr>\n<tr>\n<td>Outlet Temperature @ 30\u2103 ambient temperature<\/td>\n<td>35\u2103 (Outlet temp 5\u2103 above ambient temp)<\/td>\n<\/tr>\n<tr>\n<td>Container Certification<\/td>\n<td>China Classification Society Certification<\/td>\n<\/tr>\n<tr>\n<td>Operating Power(kW)<\/td>\n<td>20~32<\/td>\n<\/tr>\n<tr>\n<td>Motor Rated Voltage and Frequency<\/td>\n<td>400V\u00b15% 50\/60Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr class=\"title\">\n<td>Detailed Characteristics<\/td>\n<td colspan=\"1\"><\/td>\n<\/tr>\n<tr>\n<td>Shipping Weight(T)<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>Operating Weight\uff08T\uff09<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>Connection Interface<\/td>\n<td>DN100(ISO2852 PN16)<\/td>\n<\/tr>\n<tr>\n<td>Water Resupply Pipe Interface<\/td>\n<td>DN10\uff08Tapered tube\uff09<\/td>\n<\/tr>\n<tr>\n<td>Noise Level @25\u2103, 15m<\/td>\n<td>70dBA<\/td>\n<\/tr>\n<tr>\n<td>Pipe materials<\/td>\n<td>304 stainless steel<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Specification Details For Plate Heat Exchanger<\/h2>\n<table>\n<tbody>\n<tr class=\"title\">\n<td>Product Overview<\/td>\n<td colspan=\"1\"><\/td>\n<\/tr>\n<tr>\n<td>Type<\/td>\n<td>Plate Heat Exchanger \uff08EC3 &#8211; PHE\uff09<\/td>\n<\/tr>\n<tr>\n<td>Dimensions(L*W*H)(mm)<\/td>\n<td>775*480*1069<\/td>\n<\/tr>\n<tr>\n<td>Material<\/td>\n<td>TI<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr class=\"title\">\n<td>Detailed Characteristics<\/td>\n<td colspan=\"1\"><\/td>\n<\/tr>\n<tr>\n<td>Shipping Weight(KG)<\/td>\n<td>379<\/td>\n<\/tr>\n<tr>\n<td>Operating Weight\uff08KG\uff09<\/td>\n<td>461<\/td>\n<\/tr>\n<tr>\n<td>Connection Interface<\/td>\n<td>DN100(GB\/T 9122-2010 PN16 DN100)<\/td>\n<\/tr>\n<tr>\n<td>External circulation supply liquid temperature (\u2103)<\/td>\n<td>0~30<\/td>\n<\/tr>\n<tr>\n<td>External circulation flow rate (m\u00b3\/h)<\/td>\n<td>33~110<\/td>\n<\/tr>\n<tr>\n<td>Internal circulation flow rate (m\u00b3\/h)<\/td>\n<td>100<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong style=\"font-size: 16px;\">|<\/strong><span style=\"font-size: 16px;\">\u00a0<\/span><strong style=\"font-size: 16px;\">Points For Attention<\/strong><\/h2>\n<\/div>\n<\/div>\n<div id=\"block2\" class=\"tuple\" data-v-63a32c95=\"\" data-v-1b41da19=\"\">\n<div class=\"info info-zebra-crossing-table\" data-v-63a32c95=\"\" data-v-1b41da19=\"\">\n<hr \/>\n<p>&nbsp;<\/p>\n<table class=\"width-auto\">\n<tbody>\n<tr>\n<td>1<\/td>\n<td>The cooling tower must be placed on a flat ground with a level of \u00b11 degree.<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>The surface ground needs to be hardened and aimed to hold the ANTSPACE to be stable to withstand the load of at least 25 tons.<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>The customers need to prepare a 20-ton crane to load and unload ANTSPACE and Cooling-tower.<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Stairs, walkway boards, transformers, cables, bridges, cable distribution boxes, and other external facilities are not included in ANTSPACE products.<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>If you plan to store ANTSPACE units vertically on top of one another, please advise the BITMAIN sales team regarding the preferred opening direction for the door facing the air inlet of your ANTSAPCE unit. The door opens to the left by default.<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Leave at least 2 meters of air inlet space around the cooling tower.<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>Operating elevation: lower than 2000 meters. If the height is more significant than 1000 meters and a 2500kVA transformer, the number of ANTSAPCE units installed in one ANTSPACE unit must be decreased by around 1%.<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>Environmental requirements:<br \/>\nTemperature: -25\u00b0C~40\u00b0C; Humidity 10%RH~90%RH;<br \/>\nThe ambient temperature requirement in high-humidity areas is not higher than 40\u00b0C. When the ambient temperature is lower than 0\u00b0C, the inlet and outlet shutters need to be closed, and the interior of the mining machine can only be started when it is heated to above 20\u00b0C.<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>The ambient temperature of the ANTSPACE does not represent the ambient temperature of the mining machine.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"block3\" class=\"tuple\" data-v-63a32c95=\"\" data-v-1b41da19=\"\">\n<div class=\"info\" data-v-63a32c95=\"\" data-v-1b41da19=\"\">\n<p><strong>|<\/strong>\u00a0<strong>Purchasing Guidelines<\/strong><\/p>\n<hr \/>\n<p><strong>NOTES<\/strong><\/p>\n<p>2. The pictures shown are for reference only; the final shipment version shall prevail.<\/p>\n<p><strong>SHIPPING DETAILS<\/strong><\/p>\n<p>1. Shipments will be scheduled\u00a0on a first-paid-first-ship basis for orders on which BITMAIN has received full payment.<\/p>\n<p>2. You are responsible for any customs delays or returned shipments due to a lack of proper documentation. It&#8217;s highly recommended to be aware of local customs clearance policies and prepare all customs documentation ahead of time to avoid delays or unexpected costs.<\/p>\n<p><strong>WARRANTY<\/strong><\/p>\n<p>1. A 365-day warranty period is provided starting from the shipping date. BITMAIN will cover shipping costs when shipping a replacement unit within the warranty period.<\/p>\n<p>2. The warranty only applies to the original purchaser who purchased the machine directly from BITMAIN. Once the miner is resold, warranty coverage becomes the responsibility of the re-seller.<\/p>\n<p>3. If the user fails to use the product per the given instructions, specifications, and conditions provided or changes the function settings of the unit without BITMAIN&#8217;s prior consent, BITMAIN will not be liable for any damage arising therefrom.<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<div class=\"product-title\" data-v-d58547f6=\"\" data-v-63a32c95=\"\" data-v-1b41da19=\"\">\n<p class=\"text\" data-v-d58547f6=\"\">EC1-DWT<\/p>\n<\/div>\n<div class=\"product-parameters\" data-v-39f1a18d=\"\" data-v-63a32c95=\"\" data-v-1b41da19=\"\">\n<div class=\"dimensions\" data-v-39f1a18d=\"\">\n<table class=\"title-box\" data-v-39f1a18d=\"\">\n<tbody>\n<tr data-v-39f1a18d=\"\">\n<td data-v-39f1a18d=\"\">Specifications<\/td>\n<td class=\"parameter\" data-v-39f1a18d=\"\"><span data-v-39f1a18d=\"\">1030KW<\/span>\u00a0<span data-v-39f1a18d=\"\">210 Rack Space<\/span><\/td>\n<\/tr>\n<tr data-v-39f1a18d=\"\">\n<td data-v-39f1a18d=\"\">Price<\/td>\n<td class=\"price\" data-v-39f1a18d=\"\">\n<div class=\"price-unit\" data-v-39f1a18d=\"\"><span class=\"text-blue\" data-v-39f1a18d=\"\">150,000 $\/Unit<\/span><\/div>\n<\/td>\n<\/tr>\n<tr data-v-39f1a18d=\"\">\n<td data-v-39f1a18d=\"\">\n<div class=\"ex-tips top\" data-v-5c4e3f48=\"\" data-v-39f1a18d=\"\"><i class=\"bt-icon text-blue text-sm\" data-v-39f1a18d=\"\" data-v-5c4e3f48=\"\">\ue601<\/i><\/div>\n<p>After Coupon<\/td>\n<td class=\"price\" data-v-39f1a18d=\"\">\n<div class=\"price-unit\" data-v-39f1a18d=\"\"><span class=\"after-coupon-container\" data-v-39f1a18d=\"\"><span class=\"text-blue\" data-v-39f1a18d=\"\">105,000 $\/Unit<\/span><\/span><\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div class=\"product-description\" data-v-1ae4302e=\"\" data-v-63a32c95=\"\" data-v-1b41da19=\"\">\n<div class=\"description\" data-v-1ae4302e=\"\">\n<div class=\"item\" data-v-1ae4302e=\"\">\n<div class=\"label\" data-v-1ae4302e=\"\">Shipping Date<\/div>\n<div class=\"value\" data-v-1ae4302e=\"\"><span class=\"status\" data-v-1ae4302e=\"\">SPOT<\/span>\u00a0<span data-v-1ae4302e=\"\">Shipping in 30 working days after fully paid<\/span><\/div>\n<\/div>\n<div class=\"item\" data-v-1ae4302e=\"\">\n<div class=\"label\" data-v-1ae4302e=\"\">Payment Method<\/div>\n<div class=\"value\" data-v-1ae4302e=\"\"><span class=\"pay-method\" data-v-1ae4302e=\"\">USD<\/span><span class=\"pay-method\" data-v-1ae4302e=\"\">BTC<\/span><span class=\"pay-method\" data-v-1ae4302e=\"\">ETC<\/span><span class=\"pay-method\" data-v-1ae4302e=\"\">USDC(ERC20)<\/span><span class=\"pay-method\" data-v-1ae4302e=\"\">USDT(ERC20\/TRC20)<\/span><\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"featured_media":4042,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.nanosoft.sd\/store\/wp-json\/wp\/v2\/product\/4041"}],"collection":[{"href":"https:\/\/www.nanosoft.sd\/store\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.nanosoft.sd\/store\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.nanosoft.sd\/store\/wp-json\/wp\/v2\/comments?post=4041"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.nanosoft.sd\/store\/wp-json\/wp\/v2\/media\/4042"}],"wp:attachment":[{"href":"https:\/\/www.nanosoft.sd\/store\/wp-json\/wp\/v2\/media?parent=4041"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}